Classes
|
Foam (Gals)
|
CO2 (lbs)
|
Dry Chemical (lbs)
|
Halon (lbs)
|
|
B-I (Type B, Size I)
|
1.25
|
4
|
2
|
2.5
|
|
B-II (Type B, Size II)
|
2.5
|
15
|
10
|
10
|
Fire extinguishers are required on boats if any of the following conditions exist:
Fire Extinguisher Maintenance
Inspect extinguishers monthly to make sure that:
Fire extinguishers that do not satisfy the above requirements or that have been partially emptied must be replaced or taken to a qualified fire extinguisher servicing company for recharge.
Required Number of Fire Extinguishers
The number of fire extinguishers required on a recreational boat are based on the overall length of the boat. The following chart lists the number of extinguishers that are required. In the case where a Coast Guard approved pre-engineered fire extinguishing system is installed for the protection of the engine compartment, the required number of units may be reduced in accordance with the chart.
|
Minimum number of hand portable fire extinguishers required:
|
||
|
Vessel Length
|
No Fixed System
|
W/Approved Fixed Systems
|
|
Less than 26'
|
1 B-I
|
0
|
|
26' to less than 40'
|
2 B-1 or 1 B-II
|
1 B-I
|
|
40' to 65'
|
3 B-I or 1 B-II and 1 B-I
|
2 B-1 or 1 B-II
|
Approved extinguishers must be inspected and tagged by a recognized fire extinguisher servicing company within 1 year of the examination, to be credited as one of the required fire extinguishers. The pressure gauge alone is not an accurate indicator that Halon extinguishers are full. The weight of the units should be checked regularly. It is recommended that portable extinguishers be mounted in a readily accessible position.
702 South Rohlwing Road, Addison, Illinois 60101 MAP | 530 Lark Unit C, Geneva, Illinois 60134 MAP | phone: 1-888-ILLFIRE | email: info@illinoisfire.com